Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Anesthesia |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Main body :High-strength engineering plastic rack, light,beautiful and corrosion resistant |
2. Scope of application:adult, child |
3. Gas source:O2: 0.27~0.55MPa N2O: 0.27~0.55MPa |
4. Flow meter:O2: 0.1~10L/min N2O: 0.1~10L/min |
5. O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. |
6. Respiratory circuit :working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa |
7. Respiratory bellows:bellows for adults, bellows for children
tidal volume range:0~1,500 ml |
Ventilator:
1. Display mode High-definition TFT color LCD screen display
2. Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL,
SIGH, (IMV, VCV, PCV)
3. Ventilation parameters Tidal volume 50~1500 ml (20~1500 ml)
Rate 1~99 bpm
SIMV rate 2~20 bpm
I:E 2:1~1:8 (4:1~1:8)
Inspiratory trigger pressure -1.0~2.0Kpa
PEEP 0~2.0Kpa
Pressure Range 1.0~6.0Kpa
SIGH 1.5 times the inspiratory time (70-150 adjustable)
Inspiratory platform 0~50%
4. Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance,flow
-volume oop,pressure-volume loop)
5. Monitoring of oxygen concentration 21%~100%
6. Security Alarm System
Oxygen Concentration alarm upper limit setting range 21%~100%
low limit setting range 10%~80%
Airway pressure alarm upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there
is no tidal volume input for 15 seconds
Power alarm
6. Power AC 220V±10% 50Hz±1Hz
(UPS, Storage battery)
7. (Mechanical Arms)
8. (End-expiratory CO2 monitoring)
Main products:
FAQ:
Q: How to purchase your products ?
A: You can contact with us and purchase from our company directly. Normal procedure is: offer, sign contract, payment and shipment.
Q: What's the warranty for the products ?
A: The free warranty is one year from the date of commissioning qualified. However, we will still provide good after-sales service after warranty period.
Q: Can we visit your factory ?
A: Of course, welcome to visit our factory if you come to China.
Q: How long is the validity of quotation ?
A: Generally, our price is valid within one month from the date of quotation. The
price will be adjusted appropriately as the price fluctuation of raw material in
the market.
Q: What's the production date after we confirm the order ?
A: This depends on the quantity. Normally, for the mass production, we need about
7-10 days to finish the production.